Euro Dental 2018: Micro-leakage of indirect nano-hybrid resin composite inlay restorations fabricated using flexible die versus stone die after 24 hours and 3 months: An in vitro study

Sayed A. Karim, Olfat Elsayed Hassanien and Asmaa Yassen

A total number of 44 sound non-cavitated freshly extracted upper human premolar teeth were selected for this study. Teeth were randomly divided into two main groups according to the die material. Each group was subdivided according to the storage period, after 24 hours and after 3 months with 11 teeth in each. Two Way ANOVA used to compare between tested die materials and the time intervals for mean microleakage (mm) and dimensional changes (%).One-Way ANOVA used to for interaction between variables followed by Tukey’s post hoc test for pairwise comparison. Cavity preparation: A specimen was prepared according to the principles of indirect composite restoration preparation. Specimens were centralized and fixed in the CNC machine whereby the cavity walls diverged 8-10˚ over mesial and distal surfaces were

Haftungsausschluss: Diese Zusammenfassung wurde mithilfe von Tools der künstlichen Intelligenz übersetzt und wurde noch nicht überprüft oder verifiziert.